Flammability Test Chamber

IEC60695 glow wire flammability index test chamber

Brand: SZBONAD

Product Number: BND-ZRS

The glow wire flammability index test chamber is manufactured according to the IEC60695 series standard and meets the requirements of IEC 60335 clause 30, IEC 60598, UL746A and other standards. It is used to simulate the thermal stress test caused to the heating element or heat source (such as overload resistor or ignition source) in a short time. It is suitable for fire hazard tests of electronic and electrical products, household appliances and other materials. It can also be used for combustion tests without flame ignition source to test the starting temperature and flammability index of related heating wires.

GET A QUOTE

Glow Wire Flammability Index Laboratory Test Principle:

The glow wire tester heats the heating wire (Φ4 mm nickel-chromium wire) of specified material (Ni80/Cr20) and shape to the test temperature (550℃~960℃ for 1min) with a large current, and then vertically burns the test sample with a specified pressure (1.0N) for 30s. The fire hazard of finished electrical and electronic equipment is determined by whether the test sample and the bedding ignite or the burning time; the ignition property, ignition temperature (GWIT), flammability and flammability index (GWFI) of solid insulating materials and other solid combustible materials are determined.

Glow Wire Test Chamber Application:

The glow wire test chamber is suitable for the research, production and quality inspection departments of lighting equipment, low-voltage electrical appliances, electrical instruments, and other electrical and electronic products and their components.

Glow Wire Test Chamber Technical Parameters:

Glow wire temperature 500 ~ 1000 ℃ ± 2 ℃adjustable
Heating time 0-999.9s ± 0.1s,adjustable (normally choose to 30s)
Ignition timer 0-999.9s ± 0.1s, automatically records, manually suspended
Thermocouple Φ0.5mm sheathed K-type thermocouple.
Flame extinguish time 0-999.9s ± 0.1s, automatically records, manually suspended
Glow wire Φ4 mm nickel chromium wire.
hot depth 7mm ± 0.5mm (to maintain the pressure of 1N ± 0.2N hot products into the test)
Sample frame speed about 14mm / s
the pilot background black background.
the pilot process automatic testing procedures, independent ventilation
reference IEC60695-2-10, UL746A,GB/T5169.10-2006
Studio volume 0.5 cubic
equipment size 1000mm wide × 650mm deep × 1300mm high
power supply AC220V ± 5%, 50Hz, 0.6KVA