Multi-Channel Data Recorder – BONAD High Quality Temperature Inspection Instrument
Standards:
Our multi-channel data recorder adheres to the IEC 63206:2024 standard, ensuring top-notch compatibility and performance.
Applications:
Our data recorder is versatile and applicable across numerous fields, including:
- Equipment temperature monitoring and maintenance
- Evaluation of electronic circuit components
- Motor temperature measurement
- Fuel cell temperature assessment
- Cold storage temperature management
- Vehicle development and parts testing
- Ambient temperature surveillance
- LED light temperature recording
Features:
Our multi-channel data recorder boasts an array of user-friendly features:
- High-Visibility Display: High-brightness touch color TFT LCD screen with CCFL backlight for clarity.
- Advanced Processing: ARM microprocessor enabling multi-channel signal acquisition and monitoring.
- Secure Storage: 3459MB FLASH memory for secure, non-volatile data storage.
- Versatile Input: Fully isolated universal input accommodating multiple signals simultaneously without module changes.
- Detailed Engineering Data: Displays extensive numerical ranges with customizable engineering units.
- Comprehensive Alarms: Red alarm display for monitoring thresholds with optional relay alarm outputs.
- Language Support: Built-in GB2312 Chinese character library with customizable input methods.
- Flexible Printing Options: Supports internal/external micro-printing and automatic or manual data printing.
- Convenient Interface: Standard USB2.0 for easy data transfer and operation.
- Reliable Communication: Standard serial interfaces RS485, RS232, and Ethernet with Modbus RTU protocol support.
- Universal Power Supply: Operates in a wide AC voltage range from 85V to 265V.
- Power Supply Provision: Provides DC 24V power distribution for transmitters.
- Environmental Compliance: EMC III level certification for optimal performance in challenging environments.
Technical parameters:
AC/DC Power supply | 85VAV~265VA / 24VDC ±10% |
Power waste | ≤25VA(Actual power waste is related to the number of channel) |
Channel Qty | 1-64 Channel |
Input single | Thermocouple: K , E , R , B , N ,T , E , J , S , WRE5-26 , WRE3-25
Thermal: Pt100 , Cu50 Current: 4-20mA,0-10mA,0-20mA Voltage: 0-5V,0-10V,1-5V |
Accuracy | ≤±0.2%F.S |
Time Interval | 1-19999s Self-sufficient setting |
Record Capacity(68M) | 6 days(64 Channels ,1s record interval)
36days(64Channels ,1s record interval) |
Record method | Loop Record |
Alarm Type | Upper and lower alarm. 4 each channel.(Suprior limit, upper limit, lower limit, ultimate lower limit) |
Relay | TP1718 8 Channels normal open relay module 250V AC/3A (Option) |
Power supply | 1channel 24VDC power supply(Optional multi channel power supply or 5VDC power supply) |
Communication | Standard RS232C(Optional RS485 ,USB Communication , Ethernet, and GPRS wireless communication etc)
Standard ModBus RTU communication rotocol |
Working temperature | 0℃~50℃ |
Working humidity | Lower than 85%R.H( No condensation) |
Storage Temperature | -20℃~70℃ |
Storage humdit iy | Lower than 95%R.H(No condensation) |
Case Material | ABS |
Demension | 288*288*200mm |
Installation hole demension | 278*278mm |