Electrical Appliance Testing Equipment

Desktop Electrical Comprehensive Safety Tester

Brand: SZBONAD

Product Number: BND-ECS

The Desktop Electrical Comprehensive Safety Tester is a multifunctional, high-performance, and highly reliable electrical safety tester designed to ensure the safety and reliability of various electrical devices. This advanced tester can perform eight critical test functions: AC withstand voltage, DC withstand voltage, insulation resistance, grounding resistance, leakage current, AC power measurement, DC power measurement, and startup testing.

 

GET A QUOTE

With a measurement accuracy of 1.5%, this tester can display multiple measurement parameters simultaneously. It features an ARM processor and a 9-inch high-definition TFT LCD touch display for quick and precise parameter measurements. Additionally, it includes Handler and RS232 interfaces to meet diverse test communication needs.

Application

The Desktop Electrical Comprehensive Safety Tester is ideal for providing safety test solutions across various industries such as electric vehicles, power grids, photovoltaics, home appliances, information equipment, and more. It offers innovative solutions for a wide range of electrical measurements.

Relevant Standards

  • IEC 60335
  • IEC 60950
  • IEC 60601
  • IEC 61010
  • IEC 60598
  • IEC 60204

Features

  1. Comprehensive Testing: Capable of performing six joint tests including withstand voltage, insulation resistance, grounding resistance, leakage current, power measurement, and startup testing (choose 5 out of 6).
  2. Advanced Interfaces: Equipped with PLC control interface, variable frequency power supply control interface, communication interface for seamless integration with supporting facilities to enable automated testing.
  3. High Accuracy: Ensures 1.5-level safety test accuracy and 0.5-level electrical parameter test accuracy.
  4. Self-Test Function: Simplifies production operations by eliminating the need for re-testing after group changes.
  5. Standard Line Compensation: Offers more accurate calculations with enhanced line compensation functions.
  6. USB Interface: Allows mass storage of test results for efficient data management.
  7. Industry Versatility: Suitable for diverse industry requirements including home appliances, lamps, and power tools.
  8. User-Friendly Operation: Chinese menu prompts guide the operation steps making it simple and easy to understand; full digital keyboard operation enhances convenience in settings.
  9. Intelligent Analysis: Features lower limit judgment to eliminate missed detections; provides intelligent analysis and sound/light alarms for product test failures.

Main specifications:

Ground resistance test
Grounding resistance test method Four-wire system
No-load output voltage <12V
Output current setting range AC: 5.00 ~ 40.00 A continuously adjustable constant current output 50/60Hz dual frequency selectable
Output current resolution 0.1A
Output current accuracy 5.0 ~ 9.9 A:  ± (2% of set value + 0.2A)
10.0 ~ 40.0 A:  ±  (1.5% of set value)
Setting range of grounding resistance Upper limit: 0 ~ 600mΩ
Lower limit: 0 ~ 600mΩ  0 = closed
Measuring range of   grounding resistance 5.0 A ≤ Output current ≤ 10.0 A, 0 ~ 600mΩ
10.0 A ≤ Output current ≤ 20.0 A, 0 ~ 300mΩ
20.0 A ≤ Output current ≤ 40.0 A, 0 ~ 200mΩ
Grounding resistance

measurement resolution

0.1mΩ
The resistance returns to zero 0~200mΩ
Measurement accuracy of grounding resistance ±  (2% of reading + 3mΩ)
Test time setting range Output current > 20.0A, 0.1 ~ 60.0s

10.0 output current ≤ 20.0, 0.1 ~ 300.0s Output current  ≤  10 A, 0.1 ~ 999.9s

0.0, 0.1 ~ 999.9s 0.0 = continuous output

Test time resolution 0.1s
Test time accuracy ±  (0.1% of set value + 0.05s)
Insulation resistance test
Rated output load/current 1VA( 1000V/1mA)  1mA
Output Voltage Ripple Resistive load, 1000V/1mA, < 5%
Output voltage setting range DC: 100 ~ 1000V continuously adjustable
Output voltage resolution 1V
Output voltage accuracy ± (1.5% of setpoint + 3 V)
Setting range of insulation resistance Upper limit: 0,1MΩ  ~ 10GΩ  10GΩ  = OFF
Lower limit: 1 MΩ  ~ 10GΩ
Measuring range of  insulation resistance 0.50~99.99~999.9~10GΩ
Insulation resistance

measurement resolution

0.01MΩ/0.1MΩ/1MΩ
Resistance compensation > 30MΩ

Measaccuracy of insulation resistance

100~499V:

1MΩ  ~ 1GΩ:  ±  (5% reading + 0.5MΩ)

1GΩ ~ 10GΩ: for reference only, no precision requirement

500~1000V:

100MΩ  ~ 1GΩ:  ±  (5% reading + 2MΩ) 1GΩ ~ 10GΩ: ± (10% reading + 5MΩ)

Delay time 0.5~999.9s
Test time setting range 0.0, 0.1 ~ 999.9s 0.0 = continuous output
Test time resolution 0.1s
Test time accuracy ±  (0.1% of set value + 0.05s)
AC withstand voltage test
Rated output load 200VA(AC :5000V/40mA)
Output voltage regulation < 2% (empty to full)
Output voltage setting range AC: 100 ~ 5000V 50/60Hz dual frequency optional
Output voltage resolution 1V
Output voltage accuracy ±  (1.5% of setpoint + 3 V)
Measuring range of breakdown current 0.005~9.999~40.00mA
Breakdown current setting range Upper limit: 0.000 ~ 9.999 ~ 40.00 mA
Lower limit: 0.000 ~ 9.999 ~ 40.00 mA 0.000 = OFF
Breakdown current

measurement resolution

0.001mA/0.01mA
The current returns to zero 0.000~2.000mA
Breakdown current

measurement accuracy

±  (1.5% of reading + 0.01 mA)
Boost time 0.1~999.9s
Slow down the time 0.0~999.9s
Test time setting range 0.0, 0.1 ~ 999.9s 0.0 = continuous output
Test time resolution 0.1s
Test time accuracy ±  (0.1% of set value + 0.05s)
DC withstand voltage test
Rated output load 120VA( DC :6000V/10mA)
Output voltage regulation < 2% (empty to full)
Output voltage setting range DC :100~6000V
Output voltage resolution 1V
Output voltage accuracy ±  (1.5% of setpoint + 3 V)
Measuring range of breakdown current 0.005~10.00mA
Breakdown current setting range Upper limit: 0.000 ~ 10.00 mA
Lower limit: 0.000 ~ 10.00 mA 0.000 = OFF
Breakdown current

measurement resolution

0.001mA/0.01mA
The current returns to zero 0.000~2.000mA
Breakdown current

measurement accuracy

±  (2% of reading + 0.01 mA)
Boost time 0.1~999.9s
Slow down the time 0.0~999.9s
Test time setting range 0.0, 0.1 ~ 999.9s 0.0 = continuous output
Test time resolution 0.1s
Test time accuracy ±  (0.1% of set value + 0.05s)
Leakage current test
Rated load power range Determined  by  power  of  external  quarantine  transformer/external variable frequency power supply
Leakage type setting Static leak, dynamic leak
Analog impedance type GB/T12113(idtIEC60990)
Leakage current measuring circuit GB/T12113(idtIEC60990)
Output voltage rate Determined by external input voltage
Output voltage setting range AC :0.0~300.0V
Output voltage

measurement range

AC :5.0~300.0V
Output voltage

measurement resolution

0.1V
Output voltage

measurement accuracy

±( 1.5% +3V)
Leakage current setting range Upper limit: 0.000 ~ 9.999 ~ 20.00 mA
Lower limit: 0.000 ~ 9.999 ~ 20.00 mA 0.000 = OFF
0.005~9.999~20.00mA
Leakage current

measurement resolution

0.001mA/0.01mA
The current returns to zero 0.000~2.000mA
Leakage current

measurement accuracy

0.005 ~ 9.999mA: ± (1.5% reading + 0.005mA)
10.00 ~ 20.00 mA: ± (1.5% reading + 0.05 mA)
Test time setting range 0.0, 0.1 ~ 999.9s 0.0 = continuous output
Test time resolution 0.1s
Test time accuracy ±  (0.1% of set value + 0.05s)
AC power test
Output voltage rate Determined by external input voltage
Output voltage setting range AC :0.0~300.0V
Output voltage

measurement range

AC :0.0~300.0V
Output voltage

measurement resolution

0.1V
Output voltage

measurement accuracy

± (0.25% of reading + 0.25% of range)
Power setting range Upper limit: 0 ~ 6000W
Lower limit: 0 ~ 6000W 0 = off
Power measurement range 5.0~999.9~6000W
Power measurement resolution 0.1W/1W
Power measurement ±  (0.25% of reading + 0.25% of range)
accuracy
Current setting range Upper limit: 0.000 ~ 9.999 ~0 A
Lower limit: 0.000 ~ 9.999 ~ 25.00 A
Current measurement range 0.000~9.999~25.00A
Current measurement resolution 0.001A~0.01A
Current measurement accuracy ±  (0.25% of reading + 0.25% of range)
Delay time 0.2~999.9s
Power factor measurement range 0.100~1.000
Power factor measurement resolution 0.001
Power factor measurement accuracy ± (0.5% reading + 0.01)
Test time setting range 0.0, 0.1 ~ 999.9s 0.0 = continuous output
Test time resolution 0.1s
Test time accuracy ±  (0.1% of set value + 0.05s)
DC power test
Output voltage rate Determined by external input voltage
Output voltage setting range DC :0.0~300.0V
Output voltage

measurement range

DC :0.0~300.0V
Output voltage

measurement resolution

0.1V
Output voltage

measurement accuracy

± (0.25% of reading + 0.25% of range)
Power setting range Upper limit: 0 ~ 6000W
Lower limit: 0 ~ 6000W 0 = off
Power measurement range 5.0~999.9~6000W
Power measurement resolution 0.1W/1W
Power measurement accuracy ±  (0.25% of reading + 0.25% of range)
Current setting range Upper limit: 0.000 ~ 9.999 ~ 25.00 A
Lower limit: 0.000 ~ 9.999 ~ 25.00 A
Current measurement range 0.000~9.999~25.00A
Current measurement resolution 0.001A~0.01A
Current measurement accuracy ±  (0.25% of reading + 0.25% of range)
Delay time 0.2~999.9s
Test time setting range 0.0, 0.1 ~ 999.9s 0.0 = continuous output
Test time resolution 0.1s
Test time accuracy ±  (0.1% of set value + 0.05s)