Flammability Test Chamber

IEC 60950 A.3 Hot Flaming Oil Test Device

Brand: SZBONAD

Products Number: BND-HFO

The IEC 60950 A.3 Hot Flaming Oil Test Device is meticulously crafted in accordance with Article 4.6.2 and Appendix A.3 of GB4943.1-2011 “Information Technology Equipment Safety Part 1: General Requirements.” It also aligns with the standards set forth in IEC60950-1:2005, among others. This device is primarily utilized for testing the protective performance of fireproof enclosures used in electrical and electronic products such as electronic instruments, electrical meters, information technology equipment, and various other electrical devices.

GET A QUOTE

IEC 60950-1:2013 Annex A.3 Hot Flaming Oil Test Apparatus – BONAD Flammability Test Chamber

Test Principle:

The test procedure involves placing 10mL of a specified flammable liquid (with an average calorific value of 38MJ/L, a unit volume mass between 0.845g/mL and 0.865g/mL, and a flash point ranging from 43.5℃ to 93.5℃) into a metal spoon. This liquid is then heated to the ignition point of distillate fuel oil and burned for one minute. The spoon is rotated at a specific height (100mm) and flow rate (1mL/s) by a motor, which steadily pours the flammable liquid into the center of the sample’s opening (fireproof enclosure structure). The fireproof performance of the test product is evaluated based on whether an ignition cushion layer with a specified distance (50mm) and density (40g/m²) beneath the test product catches fire.

Main Technical Parameters:

Feature Description
Working Power Supply Single-phase AC220V±10%, 50Hz
Ambient Temperature 10℃~35℃; Relative Humidity: 30%~90%
Control Operation Mode Electrical control button operation
Oil Spoon ≥10mL capacity, flat bottom, made of stainless steel, diameter not exceeding φ65
Pour Height Adjustable from 0 to 300mm, motor-controlled
Infusion Rate Adjustable from 0 to 10mL/s
Pour Time Can be preset between 1 to 999999 seconds
Burning Time Can be preset between 1 to 999999 seconds
Sustained Burning Time Can be preset between 1 to 999999 seconds
Ignition Method Heating ignition
Overall Dimensions WDH=710X460X060mm; includes lighting and exhaust devices

Note:

  1. Exercise caution when cleaning after tests to avoid damaging the thermocouple.
  2. Regularly lubricate moving parts such as guide rails.