Safety Testing Equipment

IEC61591 Range Hood Air Volume Measurement Test Device

Brand: SZBONAD

Product Number: BND-61591

The range hood air volume measurement test device is an air volume test system developed and manufactured based on IEC61591, GB/T17713-2022 (new version), GB/T14806-2017, GB/T1236-2017, ISO5801, AMCA 210-07 and other standards. The air volume measurement test device mainly measures the corresponding curves of static pressure and air volume, air volume and speed, current, power, efficiency, etc. It can also test the test product in both suction and exhaust states.

GET A QUOTE

IEC61591 Range Hood Air Volume Measurement Test Device – Accurate and Reliable Air Volume Measurement

The air volume measurement test device adopts computer automatic measurement and control mode. The whole process of testing a test product only takes ten minutes. It can measure and plot the corresponding curves of static pressure and air volume, air volume and speed, current, power, efficiency, etc. It can also test the test product in both suction and discharge states. It has the characteristics of convenience, stability, reliability, good reproducibility, etc. It meets the test use in the scientific research and production process of related products.

Applicable products: range hoods, ventilation fans, bathroom heaters, heaters, cooling fans, axial fans, air purifiers, etc.

Test method: This machine has two test methods, fully automatic test and manual test.

Test Principle:

The actual working state of the test product is simulated in the test wind tunnel (the auxiliary fan is used to make the outlet pressure of the test product consistent with the requirement), and then the air pressure difference on both sides of the nozzle in the wind tunnel is measured. The corresponding wind speed at this time is calculated by the standard formula, and finally the air volume is obtained by multiplying it by the nozzle area and the relevant flow coefficient.

Performance and features:

  1. The device adopts a multi-nozzle wind chamber structure. The corresponding nozzle can be selected according to the measured flow rate, so one device can measure a wide range of flow rates.
  2. It can be used for both exhaust and intake tests.
  3. Equipped with an auxiliary fan, it can measure the full range performance curve with zero flow and zero static pressure.
  4. The computer and its peripheral equipment realize automatic testing, calculation and data output, and the test results are displayed and printed graphically. The human-computer dialogue operation is simple, with high precision, saving time and effort.
  5. Test items: P-Q characteristic curve (relationship between flow rate and static pressure), Q-η characteristic 1 curve (relationship between flow rate and total pressure efficiency), exhaust resistance curve corresponding to working air volume and pressure, Q-η characteristic 2 (relationship between flow rate and flow resistance efficiency), Q-η characteristic 3 (relationship between flow rate and energy consumption efficiency), flow resistance test items, and synchronous measurement of the speed, current and power of the object being tested.

Technical parameters:

Measuring range of air flow (0.06~25 cubic) / minute,or (3.6~1500 cubic) / hour,or (2.1~883)CFM
Static pressure 0~2000Pa ±0.2% Pa
Differential pressure 0~2000Pa ±0.2% Pa
Sample power supply AC 0~300V ±0.5% ,AC 0~5A ±0.5%, 0~1000W ±0.5%
Speed measurement range 0~5000 RPM ±5RPM , digital display
Air temperature 0~50℃, ±0.5℃
Air humidity 5~99% , ±5%
Atmospheric pressure 94000~106000 Pa, ± 200 Pa
Measurement item Maximum air volume,Maximum static pressure,Total pressure efficiency(at 7m3/min),Max total pressure efficiency,Fluid Dynamic Efficiency(FDE), Energy Efficiency Index(EEI)
Test object Range hood,Fan, Cooling fan, Axial flow fan, Air purifier
According to standard IEC61591:2020, GB/T17713-2022, ISO5801 ,GB/T1236, GB/T14806