IEC60598 Luminaries Safety Test Chain
Model:BND-SL
Introduction:
1Standards: IEC60598-1 (EN60598-14.26.3 )
Luminaries-Part 1: General requirements and tests
2, Test Chain is composed of copper and zinc alloy (Cu 63% Zn37%)without any surface treatment and coating , 200g/m load tensile resistance at 2.5±20%Ω according to IEC60598-1 standards.
Application:
1)Measuring chain resistance, to ensure that the range of 2.5 ± 20% Ω .
2)Measuring distance space of the SELV two parts, denoted as X,unit (/ cm).
3)Test chain ends hanging standard weight =15*X*g or 250g counterweight.
4)Install the thermocouple wire on proper position of the tested sample, and connecting with temperature inspecting instrument.
5)Sample access 0.9~1.1 times the rated voltage of power supply.
6)Placement test chain, short-circuit test.
It mainly used for lighting without insulation , accessible and opposite SELV part accidental short circuit protection test.